Skip to main content

RSWA 4.7.0

· 4 min read

Various optimizations and feature updates to TDS, Desktop Tools and Array Explorer.

TDS Download

Features

  • TDS configuration available on the web interface.
  • Notification widget for storage running out on TDS server.
  • Measurement sorting/filtering on inspection reports.
    • Measurements can be filtered by status (pass/fail/no decision).
    • When sorting by decision, measurements without decision and without measurements are sorted to the back.
  • On inspection reports, labels on images can be toggled on/off.
  • Up to 1000 inspections can be listed at once.
  • Optionally enable HSTS headers to enforce HTTPS traffic.
  • Updated jQuery library to v3.7.1.
  • Login form centered.
  • Performance improvements accross various functions.
  • API update:
    • Querying measurements possible using /measurements?type=weld&ids=1,2,4,6,...

Bugfixes

  • Corrected numbers of measurements on Product Overview statistics for imported parts.
  • Prevent disabled users from logging in if client_hide_login_user_list is set.
  • On inspection overview, multiple inspections can be selected using Shift+Left click.
  • Fix bug where deleting an inspection could leave the measurements in the database.
    • Under certain circumstances, this led to inspections displaying measurements which didn't belong there.
  • Fix size issue for C-scan images on tabular inspection reports.
  • Decluttering free mode inspections.
    • Remove unrelated info from report header.
    • Remove image carousel.
    • Remove image tab from prints.
  • Remove image tab from inspection report prints when images are hidden.
  • Fix error where C-scan pop-outs would flicker at the bottom of the page, on inspection reports.
  • Header bar scrolls with the rest of the window.
  • Corrected bug regarding imported reason IDs.

Array Explorer Download

Features

  • New Diagnostics Snapshot Tool:
    • This tool combines a collection of information on the F2 unit to help diagnose bugs and problems.
  • Header bar widget updates:
    • Sound and brightness are combined.
    • Battery indicator color changes depending on battery charge.
    • Array Explorer will display a notification if battery charge runs out.
    • Array Explorer will display a warning when the system storage runs out.
  • In the Auditor, if a measured value is out of range with respect to configured boundaries, it is highlighted in the header bar.
  • The Probe Configuration page highlights non-responsive elements.
  • The A/B/C buttons on the remote are now programmable from within Application Settings.
  • Warning during Setup, if the front plate deviates from configured stack values.
  • Array Explorer will highlight the presets tab if the user deviates from configured preset.
  • Optionally enable v3-like setup behavior:
    • Always keep the setup value of the previous measurement regardless of stack changes.
  • New inspections will always pre-select the first entry.
  • Warning in Array Explorer if TDS becomes unavailable during export.
  • Array Explorer will display a warning if it's misconfigured to point at localhost.
    • This happens on default installation, when no TDS instance is associated with the unit.
  • The logs page now also displayes log details when available.
  • Updated sqlite dependency to v3.47.1.

Bugfixes

  • Fix bug where remote wouldn't respect the Default to Continuous Mode setting.
  • Resuming a paused inspection will start at the last selected spot.
  • Fix bug where the measurement deletion dialog wouldn't display the spot name.
  • Fix bug where the refresh button on the logs page wouldn't work.
  • Auditor settings are unlocked without reloading the inspection when logging in with authorative user.
  • Header bar in the auditor omits the subscripts on free-mode inspections.

Desktop Tools Download

Features

  • Hotspots can be quickly placed on images by using the new "Plot" feature:
    • Users can simply click where the joint is supposed to be on the image, and Desktop Tools will automatically add the plot.
    • It will start with the first unmapped hotspot in order of joint names.
  • Selection of welds is maintained across various pages (Spotwelds/routes/images).
  • When importing from clipboard, Desktop Tools detects already existing welds and allows to merge from clipboard or skip entries.
  • Categories and presets display how many joints they are associated with.
  • Enable comments for parts/groups.
  • include an "About" tab in Desktop Tools containing Tessonics contact info.
  • Desktop Tools auto-selects the first user during login.
  • Desktop Tools displays common keyboard shortcuts next to the actions.

Bugfixes

  • Fix bug where refresh wouldn't work on the All Welds/Bonds page.
  • Fix bug where bonds couldn't properly be removed from images.
  • Fix bug where revisions page didn't update automatically after revision creation.
  • Desktop automatically selects the first USB from the list when opening the Synchronization page.