Skip to main content

Update Procedure

At the time of writing, the SRS does not yet provide an over-the-air update procedure.

To install a new version of the SRS Auditor app or the SRS web configuration daemon, follow these steps. They assume that the SRS is reachable at 192.168.1.1.

  • Download and extract the SRS Auditor app.

  • Open a command prompt and navigate to the extracted executable.

    cd path/to/executable
  • Copy the application binary to the SRS system.

    scp srs-auditor srs@192.168.1.1:
  • Connect to the SRS system through SSH. The default password is spotweld.

    ssh srs@192.168.1.1
  • Make the SRS application binary executable.

    chmod +x srs-auditor
  • Navigate to the target location.

    cd /opt/tessonics/srs/bin
  • Optional: Create a backup of the previous SRS version.

    sudo cp srs-auditor srs-auditor_backup
  • Copy the new application to its default location.

    sudo mv ~/srs-auditor .
  • Restart the SRS service.

    sudo systemctl restart tessonics-srs-auditor.service

After that, connecting with the SRS Configurator should display the new SRS Auditor version.