Zum Hauptinhalt springen

Acquire

Acquisition configuration and measurement requests share the objects below. get acq-config reads global settings, and put acq-config uploads them. get acq carries a request and can override global settings for one measurement. See Obtaining Measurements for an example.

PULSE Object​

The PULSE object configures the ultrasonic transmitter (TX).

FieldTypeDescription
voltageNumber, voltsPulse amplitude. The allowed range is 10–55 V.
widthNumber, nanosecondsPulse width. The allowed range is 8–64 ns.

AMP Object​

The AMP object configures the analog receiver (RX).

FieldTypeDescription
hdrBooleanEnables or disables high dynamic range.
gainNumber, decibelsReceiver gain. A starting value of 20.0 dB is suggested. The allowed range is 1–40 dB.
averagingIntegerNumber of averaging passes. Use 1, 2, 4, or 8. The allowed range is 1–8.

TIMING Object​

The TIMING object controls receiver ADC timing.

FieldTypeDescription
rx-delayNumber, microsecondsDelay between TX and RX. Recommended defaults are 6–7 µs for a water-column delay line and 3 µs for a hard delay line. The allowed range is 0.2–50 µs.
rx-durationNumber, microsecondsReceiver acquisition duration. The value depends on material thickness. A suggested starting value is 4 µs. The allowed range is 0.2–30 µs.

SIGNAL Object​

The SIGNAL object groups transmitter, receiver, and ADC conversion settings.

FieldTypeDescription
pulsePULSETransmitter pulse settings.
ampAMPReceiver settings.
timingTIMINGReceiver timing settings.

MUX Object​

The MUX object configures how the probe elements are grouped while pulsing.

FieldTypeDescription
modeStringMultiplexer mode: mixed, single, or quad.

STACK Object​

The STACK object provides plate thickness hints to the algorithm.

FieldTypeDescription
frontNumber, millimetersFront plate thickness. The allowed range is 0.3–10 mm.
middleNumber, millimetersMiddle plate thickness. Use 0 for a two-plate stack. The allowed range is 0–10 mm.
backNumber, millimetersBack plate thickness. The allowed range is 0.3–10 mm.

MATERIAL Object​

The MATERIAL object describes material properties. Sound velocity is used to convert time to distance.

FieldTypeDescription
nameStringMaterial name. For a get acq override, sample velocity below 1000 m/s selects steel unless the name is aluminum. At 1000 m/s or higher, the supplied values are used.
velocityNumber, meters per secondSpeed of sound in the material. This can be omitted for common materials.

MATERIALS Object​

The MATERIALS object groups the couplant and sample materials. The documented defaults are water at 1480.0 m/s for the couplant and steel at 5890.0 m/s for the sample.

FieldTypeDescription
couplantMATERIALCouplant material.
sampleMATERIALSample material.

CONFIG Object​

The CONFIG object contains the input parameters required to acquire and process a measurement.

FieldTypeDescription
signalSIGNALTransmitter, receiver, and timing parameters.
muxMUXProbe multiplexer mode.
materialsMATERIALSCouplant and sample properties.
stackSTACKPlate thicknesses.
algorithmAlgorithm SettingsAlgorithm customization.

REQUEST Object​

The REQUEST object is the payload for a get request with the acq resource. To start a new inspection, generate a new RFC 4122 UUID and send it as inspection-uid in the first acquisition request. No separate request creates an inspection. When storage is enabled, that acquisition is saved as the first measurement tagged with the UUID. Reuse the same UUID for later measurements in that inspection. The UUID is required even when storage is disabled, though no inspection is saved then. The part and location IDs identify the part and weld. The customer ID is optional and can be empty.

FieldRequirementTypeDescription
inspection-uidRequiredUUID stringUnique identifier used to group measurements into an inspection when storage is enabled.
inspection-customer-idOptionalStringPart serial number or other customer-provided identifier. It can be empty.
part-idOptionalStringPart name, such as LHS Driver Door.
location-idOptionalStringIdentifier for a weld location within the part.
materialsOptionalMATERIALSOverrides globally configured material settings.
stackOptionalSTACKOverrides globally configured stack settings.
requirementsOptionalRequirement InfoSpot-weld criteria. See Requirement.
algorithmOptionalAlgorithm SettingsAlgorithm customization and tuning.