Skip to main content

Full API Reference

Use this reference when you know which request or response field you need to look up. For a guided first request, start with the SRS API guide. For workflow examples, see Obtaining Measurements and Managing Measurement History.

The reference follows the JSON objects used by the protocol. Field names are case-sensitive. Names such as inspection-uid and rx-delay use hyphens in JSON.

PageLook here for
Auditor ConfigApplication settings returned by get config and accepted by put config.
AcquireGlobal acquisition settings and the payload for get acq.
AlgorithmShape selection and size adjustment.
LoggingLog levels and file output.
MeasurementResults returned after an acquisition.
RequirementSpot-weld quality criteria.
StatusProtocol errors, software version, and hardware information.
StorageThe measurement database path.
TemplatePart and location presets and template endpoints.

Full Example​

This get acq packet includes every field supported by the acquisition request, with per-measurement materials, stack, requirements, and algorithm settings. The \x00 at the end represents the null byte sent after the JSON object. It is not part of the JSON text.

{
"get": "acq",
"payload": {
"inspection-uid": "b628394a-4723-430a-822b-eaff99d477c4",
"inspection-customer-id": "VEHICLE-042",
"part-id": "LHS Driver Door",
"location-id": "Weld 1",
"materials": {
"couplant": {
"name": "water",
"velocity": 1480
},
"sample": {
"name": "steel",
"velocity": 5890
}
},
"stack": {
"front": 0.8,
"middle": 0,
"back": 1.2
},
"requirements": {
"size": {
"minimum": 4,
"nominal": 5
},
"indentation": {
"minimum": 0,
"maximum": 0.5
},
"thickness": {
"minimum": 2,
"maximum": 2.5
}
},
"algorithm": {
"shape": "circle",
"size": {
"bias": 0.1
}
}
}
}\x00

For how to start an inspection and use its inspection-uid, see the REQUEST Object or Obtaining Measurements.