Acquire
Acquisition configuration and measurement requests share the objects below. get acq-config reads global settings, and put acq-config uploads them. get acq carries a request and can override global settings for one measurement. See Obtaining Measurements for an example.
PULSE Object
The PULSE object configures the ultrasonic transmitter (TX).
| Field | Type | Description |
|---|---|---|
voltage | Number, volts | Pulse amplitude. The allowed range is 10–55 V. |
width | Number, nanoseconds | Pulse width. The allowed range is 8–64 ns. |
AMP Object
The AMP object configures the analog receiver (RX).
| Field | Type | Description |
|---|---|---|
hdr | Boolean | Enables or disables high dynamic range. |
gain | Number, decibels | Receiver gain. A starting value of 20.0 dB is suggested. The allowed range is 1–40 dB. |
averaging | Integer | Number of averaging passes. Use 1, 2, 4, or 8. The allowed range is 1–8. |
TIMING Object
The TIMING object controls receiver ADC timing.
| Field | Type | Description |
|---|---|---|
rx-delay | Number, microseconds | Delay between TX and RX. Recommended defaults are 6–7 µs for a water-column delay line and 3 µs for a hard delay line. The allowed range is 0.2–50 µs. |
rx-duration | Number, microseconds | Receiver acquisition duration. The value depends on material thickness. A suggested starting value is 4 µs. The allowed range is 0.2–30 µs. |
SIGNAL Object
The SIGNAL object groups transmitter, receiver, and ADC conversion settings.
| Field | Type | Description |
|---|---|---|
pulse | PULSE | Transmitter pulse settings. |
amp | AMP | Receiver settings. |
timing | TIMING | Receiver timing settings. |
MUX Object
The MUX object configures how the probe elements are grouped while pulsing.
| Field | Type | Description |
|---|---|---|
mode | String | Multiplexer mode: mixed, single, or quad. |
STACK Object
The STACK object provides plate thickness hints to the algorithm.
| Field | Type | Description |
|---|---|---|
front | Number, millimeters | Front plate thickness. The allowed range is 0.3–10 mm. |
middle | Number, millimeters | Middle plate thickness. Use 0 for a two-plate stack. The allowed range is 0–10 mm. |
back | Number, millimeters | Back plate thickness. The allowed range is 0.3–10 mm. |
MATERIAL Object
The MATERIAL object describes material properties. Sound velocity is used to convert time to distance.
| Field | Type | Description |
|---|---|---|
name | String | Material name. For a get acq override, sample velocity below 1000 m/s selects steel unless the name is aluminum. At 1000 m/s or higher, the supplied values are used. |
velocity | Number, meters per second | Speed of sound in the material. This can be omitted for common materials. |
MATERIALS Object
The MATERIALS object groups the couplant and sample materials. The documented defaults are water at 1480.0 m/s for the couplant and steel at 5890.0 m/s for the sample.
| Field | Type | Description |
|---|---|---|
couplant | MATERIAL | Couplant material. |
sample | MATERIAL | Sample material. |
CONFIG Object
The CONFIG object contains the input parameters required to acquire and process a measurement.
| Field | Type | Description |
|---|---|---|
signal | SIGNAL | Transmitter, receiver, and timing parameters. |
mux | MUX | Probe multiplexer mode. |
materials | MATERIALS | Couplant and sample properties. |
stack | STACK | Plate thicknesses. |
algorithm | Algorithm Settings | Algorithm customization. |
REQUEST Object
The REQUEST object is the payload for a get request with the acq resource. To start a new inspection, generate a new RFC 4122 UUID and send it as inspection-uid in the first acquisition request. No separate request creates an inspection. When storage is enabled, that acquisition is saved as the first measurement tagged with the UUID. Reuse the same UUID for later measurements in that inspection. The UUID is required even when storage is disabled, though no inspection is saved then. The part and location IDs identify the part and weld. The customer ID is optional and can be empty.
| Field | Requirement | Type | Description |
|---|---|---|---|
inspection-uid | Required | UUID string | Unique identifier used to group measurements into an inspection when storage is enabled. |
inspection-customer-id | Optional | String | Part serial number or other customer-provided identifier. It can be empty. |
part-id | Optional | String | Part name, such as LHS Driver Door. |
location-id | Optional | String | Identifier for a weld location within the part. |
materials | Optional | MATERIALS | Overrides globally configured material settings. |
stack | Optional | STACK | Overrides globally configured stack settings. |
requirements | Optional | Requirement Info | Spot-weld criteria. See Requirement. |
algorithm | Optional | Algorithm Settings | Algorithm customization and tuning. |