Specifications: Spatter proof, no longer than 5 meters between Remote module to Hall sensor, Male to Female connector.
M12 X code:
Specifications: Over-Molded connector, TPE, High flex, continuous flex, 10 million bend cycles at 10x cable diameter or 20 million at 20x Cable diameter, POE 802.3at/af compliant, Cat 6A.
SMA Cable:
Specifications: 50 Ohm impedance, 90-degree connector male to 180-degree male, or both connectors 180 degrees. Use Fairview Microwave PN=FMC0202058 as reference for specs.
PSU wire Guage:
Guage information: The gauge of wire from the 120v PSU to the 24v Panel is relative to the Watts consumed by the Panel and the power supply distance from the Panel.
Voltage drops x Distance: ΔV=(2ρLI)/A. Where, ΔV = Voltage drop, ρ = Resistivity of copper, L = Distance of PSU to Panel and A =Cross sectional area of conductor.
Voltage drops allowed: The allowable voltage drop for any given distance between PSU to Panel is of 1.0V maximum.