Skip to main content

Communication

Introduction

This document outlines how to use the RSWA software to measure inspections and transfer data to and from your data service.

RSWA Desktop

Affiliating the RSWA with a Data Source

When you start the RSWA for the first time, there will not be any templates or users installed, and you will not have access to the Wi-Fi functionality. You must first affiliate the RSWA with a data source.

For RSWA devices running at least version 4.9.0, a new method of connecting the RSWA with TDS has been implemented. More details on connecting the RSWA unit to TDS this way can be found on the TDS Device Manager page.

A house icon will appear on the top toolbar. It may be colored the following ways based on connection status:

ColorStatus
WhiteConnected to TDS.
GreyNo connection with TDS, or attempting to connect to TDS.
YellowConnection timeout, or another error with connecting to TDS.
RedUnauthorized access. TDS is reachable but the unit is not authorized to establish a connection.

Device Registration

Importing Templates and Users

Templates and users can be imported via a USB drive or by the network.

Importing via USB

After creating the template revision in Desktop Tools and exporting to a USB, insert the USB key into the RSWA. Then on the homepage, click Synchronization (or Sync in version 4.0) then Update Templates.

note

You may be prompted to log into an admin or transfer account to proceed (see more about different user permissions here).

You will see the template revision listed on the page, where you can click Activate to activate it.

note

If you are importing a new template revision while there's already another different template revision, and the preexisting revision was exported from a different PC or network, you may get a warning prompt saying This revision is from a data source that differs from the one to which this device is currently associated. The example screenshot below illustrates this.

Activate Template

Importing via Wi-Fi

You can send template revisions to the RSWA unit via TDS. Visit here to read about how to send a template revision to an RSWA unit on TDS.

After this, you have two options.

Forcibly Activate the Template Revision

v4.3.0+

If you check the Force revision activation checkbox on TDS, then the revision should automaticlaly be activated without having to perform any additional steps.

Manually Activate the Template Revision

A popup should be displayed on the RSWA unit, prompting you to activate the revision. You can activate it by selecting Yes.

Activate Template Revision Popup

If you previously dismissed this popup, you can still activate the revision by following the same steps for the USB option. Open Synchronization then select Update Templates. You should see the template revision that was uplaoded from TDS. Under Source, it will say "Upload to Remote Server". Select this revision and click Activate to activate it.