Skip to main content

Header Bar

The header bar displays all the relevant information from the active measurement. All displayed values are in millimeters.

If no active measurement is selected (i.e. a new inspection is created), the header bar remains empty. Header Bar - Empty

When performing a Setup operation, it displays the measured front plate thickness. Header Bar - Setup

When performing any measurement, it displays (from left to right) the diameter, indentation and stack thickness of the joint. If no measurement value can be obtained, three dashes (---) will be displayed.

Template and Restricted Mode Inspections

For template mode inspections and restricted mode inspections, the header bar also contains the template data from Desktop Tools underneath the measured values. It displays the minimum and target diameter, the minimum and maximum indentation, and the minimum and maximum stack thicknesses. Header Bar - Template Mode

Warnings

v4.7.0

When joint thresholds as programmed in the test plan are not met (i.e. the diameter is too small, the indentation or stack thickness is out of range, etc.), the respective icon becomes highlighted in red to reflect this. In the case of the screenshot below, the measured diameter size (3.84mm) is smaller than the minimum diameter (4mm), which causes the diameter icon to become red. Header Bar - Warning Colors

For software versions 4.9.0 and newer, the parameter being violated is also highlighted in red. Header Bar - Warning Colors

Free Mode Inspections

In Free Mode Inspections, since there is no template data, the header bar is thinner to conserve space. Header Bar - Free Mode

Relative Indentation

When the Display Relative Indentation is toggled in the Application Settings, the indentation is displayed as a percentage of the front plate thickness instead of millimeters. Header Bar - Relative Indentation

Manual Diameter

When the diameter of the weld measurement is changed manually via the C-Scan Panel, the respective icon will change to reflect that. Header Bar - Manual Diameter

ABIS - Adhesive Bonds